Stay Updated with Agro Cultures News




Interdum nullam est, aliquam consequat, neque sit ipsum mi dapibus quis taciti. Ullamcorper justo, elementum pellentesque gravida quisque.

Illustrative rendering. Actual retinol is light‑sensitive; batch COA and stability data available on request.
Gold‑standard vitamin A active for anti‑aging, texture refinement and epidermal renewal. The core formulation constraint is extreme sensitivity to UV, oxygen and heat — packaging, antioxidants and delivery vehicle define shelf stability and finished‑product performance.
Batch release HPLC testing. Inclusion and microencapsulated grades use separate specs with carrier content and surface release testing.
Process: Chemical synthesis, purification, recrystallization under low‑oxygen, low‑light conditions. Filled under nitrogen purge. Oxidation control is the core process control point. Detailed process and impurity control available under NDA.
| Parameter | Specification / Method | Note |
|---|---|---|
| Assay | ≥ 99.0% (HPLC) | Inclusion grades show loaded assay |
| Detection | 325 nm | HPLC‑UV quantitation |
| Appearance | Pale yellow crystalline powder | Darkening indicates oxidation |
| Melting point | 62 ~ 64 °C | Identity check |
| Loss on drying | ≤ 0.5% | |
| Residue on ignition | ≤ 0.1% | |
| Total heavy metals | ≤ 10 ppm | Cosmetic raw material standard |
| Lead (Pb) | ≤ 0.5 ppm | |
| Arsenic (As) | ≤ 0.3 ppm | |
| Mercury (Hg) | ≤ 0.1 ppm | |
| Cadmium (Cd) | ≤ 0.5 ppm | |
| Total aerobic count | ≤ 100 cfu/g | |
| Yeast & mould | ≤ 10 cfu/g | |
| E. coli / Salmonella | Not detected | Per 25 g |
| Related retinoid impurities | Each single ≤0.3%; total ≤1.0% | Retinal, retinoic acid, cis‑isomers |
Additional tests (antioxidant compatibility, photostability, preservative challenge) available on request. The sample COA shows cis‑isomer and oxidation impurity profile, critical for formulation.
Pure retinol is oil‑soluble, practically insoluble in water. Light, heat and oxygen drive degradation. Vehicle selection and antioxidant system determine finished product shelf life.
| Dosage form | Constraint | Viable engineering path |
|---|---|---|
| Oil serum / anhydrous balm | Good solubility in oils; still prone to oxidation. | Add BHT / BHA / tocopherol; amber glass, nitrogen headspace. |
| O/W or W/O emulsion cream | Water interface accelerates oxidation; UV penetrates emulsion. | Add chelator + antioxidant system; avoid high heat homogenization. |
| Aqueous clear serum | Insoluble in water; rapid degradation without protection. | Cyclodextrin inclusion complex or solubilizer system. |
| Powder skincare / pressed powder | Crystal retinol is unstable in open powder matrix. | β‑cyclodextrin inclusion powder or microcapsule grade. |
Key formulation data: soluble in vegetable oils, ethanol, isopropyl myristate; insoluble in water. Degradation products include cis‑isomers, retinal and retinoic acid.
Pure retinol crystal is not suitable for direct addition to clear aqueous formulas. For water‑based transparent products, use our cyclodextrin inclusion grade.
Two critical questions cosmetic buyers ask: how to store raw material, and what finished‑product stability to expect.
| Item | Detail |
|---|---|
| Raw crystal shelf life | 24 months, sealed, nitrogen flushed, −20 °C, dark |
| 2–8 °C storage | 6–12 months usable; assay loss accelerates |
| Accelerated | 40 °C / 75% RH: not recommended for pure crystal |
| Sensitivities | UV light, oxygen, heat, heavy metal ions; incompatible with strong oxidants |
Full photostability and antioxidant screening data available under NDA for formulators.
| Item | Detail |
|---|---|
| Stock status | 99% crystal regularly stocked, shipped cold chain |
| Sample lead time | 3–5 business days, cold pack shipment |
| Standard order | 10–18 business days, cold chain logistics |
| Inclusion / microcapsule | Production schedule required, longer lead time |
| Capacity | Annual capacity and GMP documentation available for audit |
Cold chain freight is mandatory for pure crystalline retinol to avoid assay drop in transit.
Assay purity is not the only decision variable; delivery vehicle defines stability, irritation profile and formulation compatibility.
| Grade / attribute | Typical match | Why |
|---|---|---|
| ≥99% HPLC crystal | Oil serums, anhydrous products, custom emulsions | Highest purity; formulator controls antioxidant & encapsulation system. |
| 10% β‑CD inclusion powder | Water‑compatible formulas, powder masks, pressed powders | Suppresses odor and light degradation; free‑flowing powder. |
| Microencapsulated retinol | Mild anti‑aging lotions, sensitive‑skin lines | Controlled release, lower irritation, improved shelf stability. |
| Custom solubilized retinol | Clear aqueous toners, essence | Pre‑solubilized carrier system; formulation locked at supplier side. |
Custom loaded grades and custom shell materials for microcapsules can be developed. MOQ and stability validation timeline confirmed at quotation.
Status applies to retinol as cosmetic raw material. Finished product concentration limits, warning labels and use restrictions are formulator responsibility.
| Market | Status | Key condition |
|---|---|---|
| China | Cosmetic raw material, INCI: RETINOL | Compliant with cosmetic safety spec; usage limit and warning label required. |
| USA | Allowed cosmetic ingredient | FDA cosmetic guidance; label warnings for retinoids. |
| EU | Allowed under Cosmetics Regulation 1223/2009 | Maximum concentration limits and mandatory warnings apply. |
| Korea / ASEAN | Listed cosmetic active | Regional concentration and labelling rules differ. |
| Item | Detail |
|---|---|
| MOQ | 5 g sample / trial; 100 g minimum formal order; 1 kg standard packaging. |
| Packaging | Amber aluminum foil bag, nitrogen flushed; 1kg / 5kg lightproof HDPE drum. |
| Price drivers | Crystal vs inclusion / microcapsule, order quantity, cold‑chain shipping, GMP documentation batch testing. |
| Documents per batch | COA, MSDS, TDS. IPEC, non‑GMO, allergen statement on request. |
| Storage | −20 °C, dark, sealed, inert atmosphere; avoid repeated freeze‑thaw cycles. |
Custom & OEM: Custom loading, cyclodextrin carriers, microcapsule shell types and pre‑solubilized oil systems available. Stability testing cycle is required before mass production. Discuss a custom specification →
No fixed public price listed. Cold chain and stability testing make pricing order‑specific; quotation will include logistics and storage guidance.
Retinol (vitamin A alcohol) is the pro‑active form used in over‑the‑counter cosmetics. Retinal is one oxidation step closer; retinoic acid is prescription‑only in many markets. Our material is pure retinol, not retinal or tretinoin.
Color shift is oxidation. UV, oxygen, heat and transition metals accelerate formation of cis‑isomers and oxidation impurities. Once discolored, assay has declined and irritation risk increases. Raw material must be stored frozen and protected.
Not without a solubilization or inclusion system. Retinol is water insoluble and rapidly degrades in water. For clear aqueous formulas, select our β‑cyclodextrin inclusion grade instead of pure crystal.
Common validated system: tocopherol + BHT + EDTA‑2Na as chelator. Avoid high heat during emulsification. We can share a reference antioxidant blend with sample request.
Yes, microencapsulated grade is available. Release profile, shell material and residual solvent are controlled parameters; we provide in‑vitro release data on request.
Deep dives into stability, delivery systems and regulatory labeling for retinoid skincare.
All articles are written by our R&D and regulatory team. View all technical resources →
Tell us your formula type, target retinol loading and packaging. We will return the matching grade, COA, spec sheet and baseline stability guidance.
If your formulation is incompatible with pure crystal retinol, we will recommend the inclusion or encapsulated option clearly.